; M8RB-1.A86 -- Overlay file for MDM8xx to run with DEC RAINBOW ; Communications port. 10/06/84 ; ; This overlay adapts the MDM8xx program to the DEC Rainbow Communications ; port. ; ; You will want to look this file over carefully. There are a number of ; options that you can use to configure the program to suit your taste. ; This file places particular emphasis on using an external modem. ; ; Edit this file for your preferences then follow the "TO USE:" example ; shown below. ; ; TO USE: First edit this file filling in answers for your own ; equipment. Then assemble with ASM86.CMD or equivalent ; assembler. Then use M8CNFG to overlay the the results ; of this program to the original MDM8xx.H86 file: ; ; ASM86 M8IN-1 ; PIP MDM.H86=MDM8xx.H86,M8RP-1.H86 ; GENCMD MDM 8080 CODE[MFF0] ; ; xx in MDM8xx represents the Version number of MDM8 ; e.g.: MDM830, xx=30 ; ; Now run MDM. Have Fun ; ; = = = = = = = = = = = = = = = = = = ; ; 10/06/84 - Configured from M8GP-1 for Rainbow - Alex Soya ; 04/04/84 - First version of this file - Irv Hoff ; ; = = = = = = = = = = = = = = = = = ; BELL EQU 07H ;bell CR EQU 0DH ;carriage return ESC EQU 1BH ;escape LF EQU 0AH ;linefeed ; YES EQU 0FFH NO EQU 0 ; ; ; Change the following information to match your equipment ; PORT EQU 040H MODCTL1 EQU PORT+2 ;MODEM CONTROL PORT MODDATP EQU PORT ;MODEM DATA IN PORT MODDATO EQU PORT ;MODEM DATA OUT PORT MODDCDB EQU 10h ;CARRIER DETECT BIT MODDCDA EQU 0 ;VALUE WHEN ACTIVE BAUDRP EQU 06h ;BAUD RATE PORT MODCTL2 EQU 02h ;2ND MODEM CONTROL PORT MODRCVB EQU 1 ;BIT TO TEST FOR RECEIVE MODRCVR EQU 1 ;VALUE WHEN READY MODSNDB EQU 04h ;BIT TO TEST FOR SEND MODSNDR EQU 04h ;VALUE WHEN READY ; ; Special DEC and Z80 SIO stuff ; ; DECDTR EQU 0CH ;DTR for special DEC DTR port RSTINS EQU 18H ;RESET SIO reg. 0 REG1INS EQU 0 ;no interrupts - register 1 REG3INS EQU 0C1H ;8 Rx bits, Rx enable -register 3 REG4INS EQU 44H ;16X baud rate, 1 stop bit, no parity - register 4 REG5INS EQU 0EAH ;8 Tx bits, Tx enable, RTS, DTR - register 5 ; ORG 100H ; ; Change the clock speed to suit your system ; RS 3 ;(for "JMP START" instruction) ; PMMIMODEM DB NO ;yes=PMMI S-100 Modem 103H SMARTMODEM DB YES ;yes=HAYES Smartmodem, no=non-PMMI 104H TOUCHPULSE DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H CLOCK DB 47 ;clock speed in MHz x10, 25.5 MHz max. 106H ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc. MSPEED DB 1 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H ;6=2400 7=4800 8=9600 9=19200 default BYTDLY DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H ;default time to send character in ter- ;minal mode file transfer for slow BBS. CRDLY DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H ;default time for extra wait after CRLF ;in terminal mode file transfer NOOFCOL DB 5 ;number of DIR columns shown 10AH SETUPTST DB YES ;yes=user-added Setup routine 10BH SCRNTEST DB YES ;Cursor control routine 10CH ACKNAK DB YES ;yes=resend a record after any non-ACK 10DH ;no=resend a record after a valid-NAK BAKUPBYTE DB NO ;yes=change any file same name to .BAK 10EH CRCDFLT DB YES ;yes=default to CRC checking 10FH TOGGLECRC DB YES ;yes=allow toggling of CRC to Checksum 110H CONVBKSP DB NO ;yes=convert backspace to rub 111H TOGGLEBK DB YES ;yes=allow toggling of bksp to rub 112H ADDLF DB NO ;no=no LF after CR to send file in 113H ;terminal mode (added by remote echo) TOGGLELF DB YES ;yes=allow toggling of LF after CR 114H TRANLOGON DB YES ;yes=allow transmission of logon 115H ;write logon sequence at location LOGON RESERVED DB NO ; Resevered for future release 116H LOCONEXTCHR DB NO ;yes=local command if EXTCHR precedes 117H ;no=external command if EXTCHR precedes TOGGLELOC DB YES ;yes=allow toggling of LOCONEXTCHR 118H LSTTST DB YES ;yes=printer available on printer port 119H XOFFTST DB NO ;yes=checks for XOFF from remote while 11AH ;sending a file in terminal mode XONWAIT DB NO ;yes=wait for XON after CR while 11BH ;sending a file in terminal mode TOGXOFF DB YES ;yes=allow toggling of XOFF checking 11CH IGNORCTL DB NO ;yes=CTL-chars above ^M not displayed 11DH EXTRA1 DB 0 ;for future expansion 11EH EXITCHR DB 'E'-40H ;^E = Exit to main menu 11FH BRKCHR DB '@'-40H ;^@ = Send 300 ms. break tone 120H NOCONNCT DB 'N'-40H ;^N = Disconnect from the phone line 121H LOGCHR DB 'L'-40H ;^L = Send logon 122H LSTCHR DB 'P'-40H ;^P = Toggle printer 123H UNSAVE DB 'R'-40H ;^R = Close input text buffer 124H TRANCHR DB 'T'-40H ;^T = Transmit file to remote 125H SAVECHR DB 'Y'-40H ;^Y = Open input text buffer 126H EXTCHR DB '^'-40H ;^^ = Send next character 127H ; ; ; RS 3 ; 128H ; IN@MODCTL1: IN AL,MODCTL1 ! RET ;in modem control port 12BH DB 0,0,0,0,0,0,0 ; spares ; OUT@MODDATP: OUT MODDATO,AL ! RET ;out modem data port 135H DB 0,0,0,0,0,0,0 ; spares ; IN@MODDATP: IN AL,MODDATP ! RET ;in modem data port 13FH DB 0,0,0,0,0,0,0 ; spares ; ANI@MODRCVB: AND AL,MODRCVB ! RET ;bit to test for receive ready 149H ; CPI@MODRCVR: CMP AL,MODRCVR ! RET ;value of rcv. bit when ready 14CH ; ANI@MODSNDB: AND AL,MODSNDB ! RET ;bit to test for send ready 14FH ; CPI@MODSNDR: CMP AL,MODSNDR ! RET ;value of send bit when ready 152H ; RS 6 ; 156H ; OUT@MODCTL1: OUT MODCTL1,AL ! RET ;out modem control port #2 15BH ; OUT@MODCTL2: OUT MODCTL2,AL ! RET ;out modem control port #1 15EH ; ; LOGONPTR DW (Offset LOGON) ;for user message. 161H RS 6 ; 163H JMP@GOODBYE:JMP GOODBYE ; 169H JMP@INITMOD:JMP INITMOD ;go to user written routine 16CH RET NOP ;(by-passes PMMI routine) 170H NOP RET NOP ;(by-passes PMMI routine) 173H NOP RET NOP ;(by-passes PMMI routine) 176H NOP JMP@SETUPR: JMP SETUPR ; 178H JMP@SPCLMENU: JMP SPCLMENU ; 17BH JMP@SYSVER: JMPS SYSVER ;make sure this is SHORT Jump 17EH JMP@BREAK: JMP SENDBRK ; 180H ; ; Do not change the following eight lines. ; JMP@ILPRT: RS 3 ; 183H JMP@INBUF: RS 3 ; 186H JMP@INLNCOMP: RS 3 ; 189H JMP@INMODEM: RS 3 ; 18CH JMP@NXTSCRN: RS 3 ; 18FH JMP@TIMER: RS 3 ; 192H JMP@CTYPE: RS 3 ; 195H JMP@KEYIN: RS 3 ; 198H ; ; ; Routine to clear to end of screen. If using CLREOS and CLRSCRN, set ; SCRNTEST to YES at 010AH (above). ; CLREOS: CALL JMP@ILPRT ; 19BH DB ESC,'[','0','J',0 ; 19EH RET ; 1A3H ; CLRSCRN:JMP DEC@CLRSC ; 1A4H DB 0,0,0,0,0 ; 1A7H DB 0 ; 1ACH ; SYSVER: CALL JMP@ILPRT ; 1ADH DB 'Version for DEC Rainbow Communications Port',0 DB CR,LF,0 RET ;..... ; ; ;----------------------------------------------------------------------- ; ; NOTE: You can change the SYSVER message to be longer or shorter. The ; end of your last routine should terminate by 0600H if using the ; Hayes Smartmodem or by address 0C00H otherwise. ; ;----------------------------------------------------------------------- ; DEC@CLRSC: CALL JMP@ILPRT DB ESC,'[','2','J',ESC,'[','H',0 RET ; ; ; You can put in a message at this location which can be called up with ; CTL-O if TRANLOGON has been set TRUE. You can use several lines if ; desired. End with a 0. ; LOGON DB 'Time for a beer, a smoke and a .... !',CR,LF,0 ;..... ; ; ; Add your own routine here to send a break tone to reset some time-share ; computers, if desired. ; SENDBRK: RET ;..... ; ; ; Add your own routine here to put DTR low and/or send a break tone. ; Check other routines such as M8IN-1.A86 which is using this feature. ; GOODBYE:MOV AL,DECDTR OUT MODCTL2,AL MOV CH,3 ; Turn off DTR for 300 ms MOV AL,DECDTR NOT AL OUT MODCTL2,AL RET ; ;..... ; ; ;The following is used to initialize the Z80 SIO on execution ;of MDM8xx. ; INITMOD: MOV AL,MSPEED ; get inital baudrate value MOV CS: Byte Ptr .INITSPD,AL INITMOD1: MOV AL,0 INITSPD EQU OFFSET $ -1 MOV Byte Ptr MSPEED,AL MOV BX,Offset BDTBL MOV AH,0 ADD BX,AX MOV AL,Byte Ptr [BX] MOV CS: Byte Ptr .SETBD,AL ; MOV AL,DECDTR NOT AL OUT MODCTL2,AL ; MOV AL,0 ;select register 0 OUT MODCTL1,AL MOV AL,RSTINS OUT MODCTL1,AL MOV AL,1 ;select register 1 OUT MODCTL1,AL MOV AL,REG1INS OUT MODCTL1,AL MOV AL,3 ;select register 3 OUT MODCTL1,AL MOV AL,REG3INS OUT MODCTL1,AL MOV AL,4 ;select register 4 OUT MODCTL1,AL MOV AL,REG4INS OUT MODCTL1,AL MOV AL,5 ;select register 5 OUT MODCTL1,AL MOV AL,REG5INS OUT MODCTL1,AL MOV AL,0 SETBD EQU OFFSET $ -1 OUT BAUDRP,AL RET ; ; ; Use the 'SET' command to select a desired baud rate ; SETUPR: MOV DX,(Offset BAUDBUF) ;point to new input buffer CALL JMP@ILPRT DB 'Input Baud Rate (300, 600, 1200, 2400, 4800, 9600): ',0 CALL JMP@INBUF MOV DX,(Offset BAUDBUF)+2 CALL JMP@INLNCOMP ;compare BAUDBUF+2 with characters below DB '300',0 JNB OK300 ;go if got match CALL JMP@INLNCOMP DB '600',0 JNB OK600 CALL JMP@INLNCOMP DB '1200',0 JNB OK1200 CALL JMP@INLNCOMP DB '2400',0 JNB OK2400 CALL JMP@INLNCOMP DB '4800',0 JNB OK4800 CALL JMP@INLNCOMP DB '9600',0 JNB OK9600 CALL JMP@ILPRT ;all matches failed, tell operator DB '++ Incorrect entry ++',CR,LF,BELL,0 JMP SETUPR ;try again ; OK300: MOV AL,1 ;MSPEED 300 baud value JMPS LOADBD ;go load everything ; OK600: MOV AL,3 JMPS LOADBD ; OK1200: MOV AL,5 JMPS LOADBD ; OK2400: MOV AL,6 JMPS LOADBD ; OK4800: MOV AL,7 JMPS LOADBD ; OK9600: MOV AL,8 ; ; LOADBD: MOV CS: Byte Ptr .INITSPD,AL JMP INITMOD1 ;reinitialize to new baudrate, then done ;... ; ; TABLE OF BAUDRATE PARAMETERS ; BD110 EQU 0 ;110 baud NOT SUPPORTED BD300 EQU 66H ;300 baud BD450 EQU 0 ;450 baud NOT SUPPORTED BD600 EQU 77H ;600 baud BD710 EQU 0 ;710 baud NOT SUPPORTED BD1200 EQU 88H ;1200 baud BD2400 EQU 0BBh ;2400 baud BD4800 EQU 0DDh ;4800 baud BD9600 EQU 0EEH ;9600 baud BD19200 EQU 0 ;19200 baud NOT SUPPORTED ; BAUDBUF DB 10,0 RS 10 BDTBL DB BD110,BD300,BD450,BD600,BD710,BD1200,BD2400,BD4800,BD9600,BD19200 ; ; ; ; If using the Hayes Smartmodem this is unavailable without a special ; change. ; SPCLMENU: RET ; ; ; NOTE: MUST TERMINATE PRIOR TO 0600H (with Smartmodem) ; 0C00H (without Smartmodem) ;..... ; END