TITLE 'ZENITH 100 OVLY' ; M8HZ.A86 -- Zenith 100 overlay file for MDM8xx. 09/28/84 ; ; This overlay adapts the MDM8xx program to the 2661 EPCI serial I/O ; chip used in the Zenith 100 series. ; ; You will want to look this file over carefully. There are a number of ; options that you can use to configure the program to suit your taste. ; ; Edit this file for your preferences then follow the "TO USE:" example ; shown below. ; ; TO USE: First edit this file to chose your options. ; Then assemble with ASM86.CMD or equivalent ; assembler. Then use M8CNFG to overlay the ; the results of this program to the original ; MDM8xx.H86 file: ; ; ASM86 M8HZ-1 ; REN M8OVL.H86=M8HZ-1.H86 ; M8CNFG ; GENCMD MDM 8080 CODE[MFF0] ; ; Now run MDM. Have Fun ; ; = = = = = = = = = = = = = = = = = = ; ; 09/28/84 - Modified GP overlay for Z100 - Dennis Vallianos ; 09/21/84 - Converted for use with MDM830 - Alex Soya ; 01/10/83 - Original version for MDM701 - Irv Hoff ; ; = = = = = = = = = = = = = = = = = ; YES EQU 0FFH NO EQU 0 ; ; BELL EQU 07H ;bell CR EQU 0DH ;carriage return ESC EQU 1BH ;escape LF EQU 0AH ;linefeed ; ; ; Zenith 100 specific communications port data ; MODDATP EQU 0ECH ;modem data in port MODCTL1 EQU 0EDH ;modem control port MODCTL2 EQU 0EDH ;modem control port MODMODE EQU 0EEH ;modem mode port MODCMD EQU 0EFH ;modem command port ; MODRCVB EQU 2 ;bit to test for receive MODRCVR EQU 2 ;value when ready MODSNDB EQU 1 ;bit to test for send MODSNDR EQU 1 ;value when ready ; ORG 100H RS 3 ;(for "JMP START" instruction) ; ; User options. ; Change the clock speed to suit your system (defaults to 1200 baud). ; ; PMMIMODEM DB NO ;yes=PMMI S-100 Modem 103H AUTODIAL DB NO ;yes=HAYES-likem no=non-PMMI 104H TOUCHPULSE DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H CLOCK DB 49 ;clock speed in MHz x10, 25.5 MHz max. 106H ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc. MSPEED DB 5 ;0=110 1=300 2=450 3=600 4=710 5=1200 107H ;6=2400 7=4800 8=9600 9=19200 default BYTDLY DB 5 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H ;default time to send character in ter- ;minal mode file transfer for slow BBS. CRDLY DB 5 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H ;default time for extra wait after CRLF ;in terminal mode file transfer NOOFCOL DB 5 ;number of DIR columns shown 10AH SETUPTST DB YES ;yes=user-added Setup routine 10BH SCRNTEST DB YES ;cursor control routine 10CH RETRY DB NO ;yes=reset the error limit to try again 10DH ;no=abort after 10 consecutive errors BAKUPBYTE DB NO ;yes=change any file same name to .BAK 10EH CRCDFLT DB YES ;yes=default to CRC checking 10FH TOGGLECRC DB YES ;yes=allow toggling of CRC to Checksum 110H CONVRUB DB NO ;yes=convert rub to backspace 111H TOGGLELRUB DB YES ;yes=allow toggling of rub to backspace 112H ADDLF DB NO ;no=no LF after CR to send file in 113H ;terminal mode (added by remote echo) TOGGLELF DB YES ;yes=allow toggling of LF after CR 114H TRANLOGON DB YES ;yes=allow transmission of logon 115H ;write logon sequence at location LOGON RESERVED DB NO ;resevered for future release 116H LOCONEXTCHR DB NO ;yes=local command if EXTCHR precedes 117H ;no=external command if EXTCHR precedes TOGGLELOC DB YES ;yes=allow toggling of LOCONEXTCHR 118H LSTTST DB YES ;yes=printer available on printer port 119H XOFFTST DB NO ;yes=checks for XOFF from remote while 11AH ;sending a file in terminal mode XONWAIT DB NO ;yes=wait for XON after CR while 11BH ;sending a file in terminal mode TOGXOFF DB YES ;yes=allow toggling of XOFF checking 11CH IGNORCTL DB YES ;yes=CTL-chars above ^M not displayed 11DH EXTRA1 DB 0 ;for future expansion 11EH EXITCHR DB 'E'-40H ;^E = Exit to main menu 11FH BRKCHR DB 'B'-40H ;^B = Send 300 ms. break tone 120H NOCONNCT DB 'N'-40H ;^N = Disconnect from the phone line 121H LOGCHR DB 'L'-40H ;^L = Send logon 122H LSTCHR DB 'P'-40H ;^P = Toggle printer 123H UNSAVE DB 'R'-40H ;^R = Close input text buffer 124H TRANCHR DB 'T'-40H ;^T = Transmit file to remote 125H SAVECHR DB 'Y'-40H ;^Y = Open input text buffer 126H EXTCHR DB '\'-40H ;^\ = Send next character 127H ; ; ; RS 3 ; 128H ; IN_MODCTL1: IN AL,MODCTL1 ! RET ;in modem control port 12BH DB 0,0,0,0,0,0,0 ; spares ; OUT_MODDATP: OUT MODDATP,AL ! RET ;out modem data port 135H DB 0,0,0,0,0,0,0 ; spares ; IN_MODDATP: IN AL,MODDATP ! RET ;in modem data port 13FH DB 0,0,0,0,0,0,0 ; spares ; ANI_MODRCVB: AND AL,MODRCVB ! RET ;bit to test for receive ready 149H ; CPI_MODRCVR: CMP AL,MODRCVR ! RET ;value of rcv. bit when ready 14CH ; ANI_MODSNDB: AND AL,MODSNDB ! RET ;bit to test for send ready 14FH CPI_MODSNDR: CMP AL,MODSNDR ! RET ;value of send bit when ready 152H ; RS 6 ; 156H ; OUT_MODCTL1: OUT MODCTL1,AL ! RET ;out modem control port #2 15BH ; OUT_MODCTL2: OUT MODCTL2,AL ! RET ;out modem control port #1 15EH ; ; LOGONPTR DW (OFFSET LOGON) ;for user message. 161H RS 6 ; 163H JMP_GOODBYE: JMP GOODBYE ; 169H JMP_INITMOD: JMP INITMOD ;go to user written routine 16CH RET NOP ;(by-passes PMMI routine) 170H NOP RET NOP ;(by-passes PMMI routine) 173H NOP RET NOP ;(by-passes PMMI routine) 176H NOP ; JMP_SETUPR: JMP SETUPR ; 178H JMP_SPCLMENU: JMP SPCLMENU ; 17BH JMP_SYSVER: JMPS SYSVER ;make sure this is SHORT Jump 17EH JMP_BREAK: JMP SENDBRK ; 180H ; ; Do not change the following sixteen lines. ; JMP_ILPRT: RS 3 ; 183H JMP_INBUF: RS 3 ; 186H JMP_INLNCOMP: RS 3 ; 189H JMP_INMODEM: RS 3 ; 18CH JMP_NXTSCRN: RS 3 ; 18FH JMP_TIMER: RS 3 ; 192H JMP_CTYPE: RS 3 ; 195H JMP_KEYIN: RS 3 ; 198H ; ; ; Routine to clear to end of screen. If using CLREOS and CLRSCRN, set ; SCRNTEST to YES at 010AH (above). ; CLREOS: CALL JMP_ILPRT ; 19BH DB ESC,'J',0,0,0 ; 19EH RET ; 1A3H ; CLRSCRN:CALL JMP_ILPRT ; 1A4H DB ESC,'E',0,0,0 ; 1A7H RET ; 1ACH ; SYSVER: CALL JMP_ILPRT ; 1ADH DB 'Version for Zenith 100 modem port J2' DB CR,LF,0 RET ;..... ; ; ;----------------------------------------------------------------------- ; ; NOTE: You can change the SYSVER message to be longer or shorter. The ; end of your last routine should terminate by 0600H if using the ; Hayes Smartmodem or by address 0C00H otherwise. ; ;----------------------------------------------------------------------- ; ; You can put in a message at this location which can be called up with ; CTL-O if TRANLOGON has been set TRUE. You can use several lines if ; desired. End with a 0. ; LOGON DB 'Hello out there!',CR,LF,0 ;..... ; ; ; Send a break tone to reset some time-share computers, if desired. ; SENDBRK:MOV AL,1DH JMP GOODBYE1 ;..... ; ; ; Routine here to put DTR low and disconnect modem. ; GOODBYE:MOV AL,0 ;selecting chip forces DTR low ; GOODBYE1: OUT MODCMD,AL IN AL,MODCMD IN AL,MODCMD MOV CH,3 ;hold for 300 ms CALL JMP_TIMER MOV AL,37H ;reset to normal OUT MODCMD,AL IN AL,MODCMD IN AL,MODCMD MOV AL,0 RET ;..... ; ; ; The following routine initializes the 2661B I/O port. ; INITMOD:MOV AL,0 ;select chip OUT MODCMD,AL IN AL,MODCMD IN AL,MODCMD MOV AL,4EH ;async., 8 bits, 1 stop, no parity OUT MODMODE,AL MOV BL,BYTE PTR MSPEED ;get baud rate DEC BL ;adjust for table offset XOR BH,BH ;make 16 bit MOV AL,BYTE PTR BDTBL[BX] OUT MODMODE,AL ;set baud rate MOV AL,37H ;async, RTS, DTR, etc. OUT MODCMD,AL IN AL,MODCMD IN AL,MODCMD MOV AL,0 ;clear register RET ;..... ; ; Use the 'SET' command to select a desired baud rate. ; SETUPR: MOV DX,OFFSET BAUDBUF CALL JMP_ILPRT DB 'Input Baud Rate (300, 1200, 2400, 4800, 9600): ',0 CALL JMP_INBUF ;get user's input MOV DX,(OFFSET BAUDBUF)+2 CALL JMP_INLNCOMP ;compare BAUDBUF+2 with chars. below DB '300',0 JNB OK300 CALL JMP_INLNCOMP DB '1200',0 JNB OK1200 CALL JMP_INLNCOMP DB '2400',0 JNB OK2400 CALL JMP_INLNCOMP DB '4800',0 JNB OK4800 CALL JMP_INLNCOMP DB '9600',0 JNB OK9600 CALL JMP_ILPRT ;failed to match - tell operator DB '++ Incorrect entry ++',CR,LF,BELL,0 JMP SETUPR ;try again ; OK300: MOV AL,1 JMPS LOADBD ; OK1200: MOV AL,5 JMPS LOADBD ; OK2400: MOV AL,6 JMPS LOADBD ; OK4800: MOV AL,7 JMPS LOADBD ; OK9600: MOV AL,8 JMPS LOADBD ; OK19200: MOV AL,9 ; LOADBD: MOV BYTE PTR MSPEED,AL ;change so messages are ok JMP INITMOD ;reinitialize chip to new speed ; ; TABLE OF BAUDRATE PARAMETERS ; BD300 EQU 0F6H BD450 EQU 0 ;450 bps NOT SUPPORTED BD600 EQU 0 ;600 bps NOT SUPPORTED BD710 EQU 0 ;710 bps NOT SUPPORTED BD1200 EQU 0F8H BD2400 EQU 0FBH BD4800 EQU 0FCH BD9600 EQU 0FDH BD19200 EQU 0FEH ; BAUDBUF DB 10,0 RS 10 ; ; Pointer table ; BDTBL DB BD300,BD450,BD600,BD710,BD1200,BD2400,BD4800,BD9600,BD19200 ; ; ; If using the Hayes Smartmodem this is unavailable without a special ; change. ; SPCLMENU: RET ; ; ; NOTE: MUST TERMINATE PRIOR TO 0600H (with Smartmodem) ; 0C00H (without Smartmodem) ;..... ; END