; B5EA-2.INS - Eagle II and Eagle III insert for BYE5 - 12/01/85 ; ; Z80 SIO and CTC 8340 timer ; ; Note: This is an insert, not an overlay. ; ; This version is for the Eagle II and III computers using channel "A" ; Z80 SIO. The Z80-CTC is used as the baud rate generator. ; ; ; NOTE: The Eagle does not support DTR on pin 20 or DCD on pin 8, so ; be sure you wire the modem cable like this: ; ; modem Eagle ; ; TXD 2 --> 3 RXD ; RXD 3 <-- 2 TXD ; GND 7 --- 7 GND ; DCD 8 --> 5 CTS ; DTR 20 <-- 4 RTS ; ; = = = = = = = = = = = = = = = = = = ; ; 12/01/85 Fixed the LOADBD routine to output correctly, thanks to ; Dennis Recla - Irv Hoff ; ; 07/17/85 Written for use with BYE5 - Irv Hoff ; ; = = = = = = = = = = = = = = = = = = ; ;----------------------------------------------------------------------- ; ; Note: For Port A, Data = 18H, CTC = 01H, Port B, Data = 1AH, CTC = 02H ; PORT EQU 18H ; Data port MDCTL1 EQU PORT+1 ; Status/control port BRPORT EQU 01H ; Baud rate port ; ; BD300: DW 47D0H ; 62400/300 (first half is CTC command) BD1200: DW 4734H ; 62400/1200 BD2400: DW 471AH ; 62400/2400 ; ; ;----------------------------------------------------------------------- ; ; See if we still have a carrier - if not, return with the zero flag set ; MDCARCK:MVI A,10H ; Reset status OUT MDCTL1 IN MDCTL1 ; Get status ANI 20H ; Check for data carrier RET ;..... ; ; ; Disconnect and wait for an incoming call ; MDINIT: MVI A,18H ; Reset channel OUT MDCTL1 MVI A,4 ; Setup to write register 4 OUT MDCTL1 MVI A,84H ;*1 stop, 8 bits, no parity, 32x OUT MDCTL1 MVI A,5 ; Setup to write register 5 OUT MDCTL1 MVI A,68H ; Clear RTS causing hangup OUT MDCTL1 PUSH B ; Save in case it's being used elsewhere MVI B,20 ; 2 seconds delay to drop any carrier ; OFFTI: CALL DELAY ; 0.1 second delay DCR B JNZ OFFTI ; Keep looping until finished POP B ; Restore bc MVI A,3 ; Setup to write register 3 OUT MDCTL1 MVI A,0C1H ; Initialize receive register OUT MDCTL1 MVI A,5 ; Setup to write register 5 OUT MDCTL1 MVI A,0EAH ; Turn on RTS so modem can answer phone OUT MDCTL1 ; IF IMODEM ; If using intelligent modem CALL IMINIT ; Go initialize ENDIF ; IMODEM ; RET ;..... ; ; ; Input a character from the modem port ; MDINP: IN PORT ; Get character RET ;..... ; ; ; Check the status to see if a character is available. If not, return ; with the zero flag set. If yes, use 0FFH to clear the flag. ; MDINST: IN MDCTL1 ; Get status ANI 01H ; Check receive ready bit RZ ; Return if none ORI 0FFH ; Otherwise, set the proper flag RET ;..... ; ; ; Send a character to the modem ; MDOUTP: OUT PORT ; Send it RET ;..... ; ; ; See if the output is ready for another character ; MDOUTST:IN MDCTL1 ANI 04H ; Check transmit ready bit RET ;..... ; ; ; Reinitialize the modem and hang up the phone by dropping DTR and ; leaving it inactive. ; MDQUIT: IF IMODEM ; If using a smartmodem CALL IMQUIT ; Tell it to shut down ENDIF ; IMODEM ; ; ; Called by the main program after caller types BYE ; MDSTOP: MVI A,5 ; Setup to write register 5 OUT MDCTL1 MVI A,68H ; Clear RTS causing shutdown OUT MDCTL1 RET ;..... ; ; ; The following routine sets the baudrate. BYE5 asks for the maximum ; speed you have available. ; SETINV: ORI 0FFH ; Make sure zero flag is not set RET ; Return ;..... ; ; SET300: LHLD BD300 ; Get 300 bps parameters in 'HL' JMP LOADBD ; Go load them ; SET1200:LHLD BD1200 JMP LOADBD ; SET2400:LHLD BD2400 ; LOADBD: MOV A,H ; CTC command word OUT BRPORT MOV A,L ; Baudrate OUT BRPORT XRA A RET ;..... ; ; end ;-----------------------------------------------------------------------