; NUCC-1.INS - NUBYE insert for CCS-2719 and SDS Z80-SIO - 04/21/86 ; ; Z80-SIO and 8430 CTC timer ; ; This version is for both the CCS-2719 and Sierra Data Science S-100 ; serial I/O boards. Note: This is an insert, not an overlay. ; ; ; IN ORDER TO USE THE CCS-2719 WITH THE SMART MODEM, WE MUST ; CHANGE THE HARDWARE SOMEWHAT. THE HEADER BLOCK ON THE 2719 ; MUST BE TURNED OVER SO THE PORT CONFIGURATION IS FOR DTE ; (DATA TERMINAL EQUIPMENT). FURTHER, THE STANDARD CCS-2719 ; PRESENTS DSR FROM THE RS-232-C TO DCD OF THE SIO. NUBYE RE- ; QUIRES THE ACTUAL DCD FROM PIN 8 OF THE RS-232-C, THEREFORE ; WE MUST REMOVE THE JUMPER IN THE HEADER BLOCK FROM PINS 1 ; AND 15 AND ADD A WIRE FROM PIN 15 OF THE FLAT CABLE HEADER ; (PIN 8 OFTHE RS-232-C) TO PIN 1 OF THE HEADER BLOCK. THIS ; WILL PUT THE MODEM'S DCD SIGNAL TO THE the SIO'S DCD INPUT. ; REFER TO THE CCS-2719 SCHEMATIC IN YOUR USER'S MANUAL. ; ; - Note by Joe Wright ; ; ======== ; ; 04/21/86 Modified for NUBYE ; 07/17/85 Written for use with BYE5 - Irv Hoff ; ; ======== ; ; Select one of the following with YES or NO ; CCS EQU YES ; CCS2719 at 3.6864 MHz for Counter mode SIERRA EQU NO ; Sierra Data Science at 4.000 MHz ; ; Set base port for SIO & CTC chips ; IF CCS PORT EQU 54H ; Data port MDCTL1 EQU PORT+1 ; Modem satus port BRPORT EQU 50H ; Baud rate generator port (CTC) ENDIF ; CCS ; IF SIERRA PORT EQU 82H ; Data port MDCTL1 EQU PORT+1 ; Modem status port BRPORT EQU 89H ; Baud rate generator port (CTC) ENDIF ; SIERRA ; MDRCV EQU 1 ; Modem receive ready bit MDSND EQU 4 ; Modem send ready bit MDDCD EQU 8 ; Data carrier detect ; ; First byte of CTC Command: ; ; To access CTC baud rate command - Note, the CCS 2719 uses the 3.6864 ; MHz xtal for the counter mode and the 4.000 MHz xtal for the timer ; mode. The SDS board uses the 4.000 MHz master clock for both. ; BDCMD1 EQU 07H ; Uses a "divide by 16" prescaler BDCMD2 EQU 47H ; Uses a "divide by 2" flip-flop ; ; The following assume CCS2719 oscillator at 1.8432 MHz. ; IF CCS BD300 EQU 52 ; 300 baud (4.000 xtal, rest 1.8432) BD1200 EQU 96 ; 1200 bps BD2400 EQU 48 ; 2400 bps BD9600 EQU 12 ; 9600 bps ENDIF ; CCS ; ; The following assume SIERRA DATA SCIENCE oscillator at 4.000 MHz. ; IF SIERRA BD300 EQU 52 ; 300 baud BD1200 EQU 104 ; 1200 bps BD2400 EQU 52 ; 2400 bps BD9600 EQU 13 ; 9600 bps ENDIF ; SIERRA ; ; ; See if we still have a carrier - if not, return with the zero flag set ; MDCARCK:MVI A,10H ; Reset status OUT MDCTL1 IN MDCTL1 ; Get status ANI MDDCD ; Check for carrier RET ; ; Disconnect and wait for an incoming call ; MDINIT: MVI A,0 ; Setup to write register 0 OUT MDCTL1 MVI A,18H ; Reset channel OUT MDCTL1 MVI A,4 ; Setup to write register 4 OUT MDCTL1 MVI A,44H ; Set 16x, 1 stop bit, no parity OUT MDCTL1 MVI A,3 ; Setup to write register 3 OUT MDCTL1 MVI A,0C1H ; 8 bits, Rx enable OUT MDCTL1 MVI A,5 ; Setup to write register 5 OUT MDCTL1 MVI A,68H ; DTR off OUT MDCTL1 PUSH B ; Save in case it's being used elsewhere MVI B,20 ; 2 second delay to drop any carrier ; OFFTI: CALL DELAY ; 1 second delay DCR B JNZ OFFTI ; Keep looping until finished POP B ; Restore 'BC' MVI A,5 ; Setup to write register 5 OUT MDCTL1 MVI A,0E8H ; Turn DTR back on OUT MDCTL1 ; IF IMODEM ; If using an intellegent modem CALL IMINIT ; Go initialize it now ENDIF ; IMODEM ; RET ; ; Input a character from the modem port ; MDINP: IN PORT ; Get character RET ; ; Check the status to see if a character is available. If not, return ; with the zero flag set. If yes, use 0FFH to clear the flag. ; MDINST: IN MDCTL1 ; Get status ANI MDRCV ; Got a character RZ ; Return if none ORI 0FFH ; Otherwise set the proper flag RET ; ; Send a character to the modem ; MDOUTP: OUT PORT ; Send it RET ; ; See if the output is ready for another character ; MDOUTST:IN MDCTL1 ; Get status ANI MDSND ; Ready for a character? RET ; ; Reinitialize the modem and hang up the phone by dropping DTR and ; leaving it inactive. ; MDQUIT: IF IMODEM CALL IMQUIT ENDIF ; IMODEM ; ; Called by the main program after caller types BYE ; MDSTOP: MVI A,5 ; Setup to write register 5 OUT MDCTL1 MVI A,68H ; Turn off DTR until next time OUT MDCTL1 RET ; ; The following routine sets the baudrate. NUBYE asks for the maximum ; speed you have available. ; SETINV: ORI 0FFH ; Make sure zero flag is not set RET ; SET300: MVI B,BD300 ; Set for 300 baud MVI A,BDCMD1 JMP SETBAUD ; SET1200:MVI B,BD1200 ; Set for 1200 bps MVI A,BDCMD2 JMP SETBAUD ; SET2400:MVI B,BD2400 ; Set for 2400 bps MVI A,BDCMD2 ; SETBAUD:OUT BRPORT ; Send first byte of command MOV A,B ; Restore the rate OUT BRPORT ; Send rate XRA A ; Say rate is ok RET ; ; end of insert ; -------------