; M7AD-4.ASM -- Coleco Adam Sydmodem overlay file for MDM7xx. 03/06/87 ; ; You will want to look this file over carefully. There are a number of ; options that you can use to configure the program to suit your taste. ; This file places particular emphasis on using the Coleco Adam equip- ; ment with 8250 serial I/O. Much of the information contained here is ; not in the main file. If not using the Coleco Adam Sydmodem equipment ; some of the routines here will illustrate what you could do with your ; unit. ; ; Use the "SET" command to change baudrate when desired. ; ; Edit this file for your preferences then follow the "TO USE:" example ; shown below. ; ; ; TO USE: First edit this file filling in answers for your own ; equipment. Then assemble with ASM.COM or equivalent ; assembler. Then use DDT to overlay the the results ; of this program to the original .COM file: ; ; A>DDT MDM7xx.COM ; DDT VERS 2.2 ; NEXT PC ; 4A00 0100 ; -IM7AD-2.HEX (note the "I" command) ; -R ("R" loads in the .HEX file) ; NEXT PC ; 4A00 0000 ; -G0 (return to CP/M) ; A>SAVE 73 MODEM7xx.COM (now have a modified .COM file) ; ; NOTE: If the MDM7XX file gets bigger the SAVE XX will be ; larger. Be sure to check the hex number under NEXT.. ; = = = = = = = = = = = = = = = = = = ; ; 22/06/87 - fixed disconnect bug..................Syd Carter ; 12/05/87 - Somewhere around this date added a buffer for Adams slow screen ; scroll problem at 1200 baud speed. ; Syd Carter ; SAME GUY ; 06/03/87 - Converted H8-4A to M7AD-2 for the Adam Sydmodem..Syd Carter ; 03/16/84 - Added SMARTMODEM EQU so IF/ENDIF statements would work ; M7H8-4A work corectly. - Mike Allen ; 02/26/84 - Corrected to allow SMARTMODEM YES without overrunning ; M7H8-4 0400H in assembly. - Bill Wood ; ; 02/15/84 - Made default baud-rate follow the MSPEED equate. ; M7H8-3 - Rich Berg ; ; 12/11/83 - Restricted baud-rate selection for Hayes users. ; M7H8-2 changed signon for Hayes, tells default modem ; speed at signon. - Tom Bering ; ; 11/11/83 - Renamed to M7H8-1.ASM, no changes - Irv Hoff ; 10/03/82 - First version of this file ; ; = = = = = = = = = = = = = = = = = ; BDOS EQU 0005 BUFLEN EQU 01fh WRITEPOS EQU 0FF20H READPOS EQU 0FF21H CBUFFER EQU 0FF22H BELL: EQU 07H ;bell CR: EQU 0DH ;carriage return ESC: EQU 1BH ;escape LF: EQU 0AH ;linefeed ; YES: EQU 0FFH NO: EQU 0 ; ; ; Change the value at MODDATP if it does not match what you are using. ; MODDATP: EQU 050H ;data port for Sydmodem MODCTL1: EQU MODDATP+5 ;status port for Sydmodem MODRCVB: EQU 1 ;bit to test for received data MODRCFE: EQU 8 ;MODEM FRAMING ERROR MODRCVR: EQU 1 ;modem receive ready MODSNDB: EQU 20H ;bit to test for ready to send MODSNDR: EQU 20H ;modem send ready bit ; SMARTMODEM: EQU YES ;yes=HAYES SmartModem, no=non-Hayes ;put here to make 'IF-ENDIF' happy ; ORG 100H ; ; Change the clock speed if needed, to match your system ; DS 3 ;(for "JMP START" instruction) ; PMMIMODEM: DB NO ;yes=PMMI S-100 Modem 103H SMODEM: DB SMARTMODEM ;now prog & 'IF-ENDIF' happy 104H TOUCHPULSE: DB 'T' ;T=touch, P=pulse (Smartmodem-only) 105H CLOCK: DB 37 ;clock speed in MHz x .1, 25.5 MHz max. 106H ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc. MSPEED: DB 5 ;set to desired default. 1=300 2=450 107H ;4=600 5=1200 8=9600 BYTDLY: DB 1 ;0=0 delay 1=10ms 5=50 ms - 9=90 ms 108H ;default time to send character in ter- ;minal mode file transfer for slow BBS. CRDLY: DB 1 ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H ;default time for extra wait after CRLF ;in terminal mode file transfer NOOFCOL: DB 2 ;number of DIR columns shown 10AH SETUPTST: DB YES ;yes=user-added Setup routine 10BH SCRNTEST: DB NO ;Cursor control routine 10CH ACKNAK: DB YES ;yes=resend a record after any non-ACK 10DH ;no=resend a record after a valid NAK BAKUPBYTE: DB NO ;yes=change any file same name to .BAK 10EH CRCDFLT: DB YES ;yes=default to CRC checking 10FH TOGGLECRC: DB YES ;yes=allow toggling of CRC to Checksum 110H CONVBKSP: DB YES ;yes=convert backspace to rub 111H TOGGLEBK: DB YES ;yes=allow toggling of bksp to rub 112H ADDLF: DB NO ;no=no LF after CR to send file in 113H ;terminal mode (added by remote echo) TOGGLELF: DB YES ;yes=allow toggling of LF after CR 114H TRANLOGON: DB YES ;yes=allow transmission of logon 115H ;write logon sequence at location LOGON SAVCCP: DB YES ;yes=do not overwrite CCP 116H LOCONEXTCHR: DB NO ;yes=local command if EXTCHR precedes 117H ;no=external command if EXTCHR precedes TOGGLELOC: DB YES ;yes=allow toggling of LOCONEXTCHR 118H LSTTST: DB YES ;yes=printer available on printer port 119H XOFFTST: DB YES ;yes=checks for XOFF from remote while 11AH ;sending a file in terminal mode XONWAIT: DB NO ;yes=wait for XON after CR while 11BH ;sending a file in terminal mode TOGXOFF: DB YES ;yes=allow toggling of XOFF checking 11CH IGNORCTL: DB YES ;yes=CTL-chars above ^M not displayed 11DH EXTRA1: DB 0 ;for future expansion 11EH EXTRA2: DB 0 ;for future expansion 11FH BRKCHR: DB '@'-40H ;^@ = Send a 300 ms. break tone 120H NOCONNCT: DB 'N'-40H ;^N = Disconnect from the phone line 121H LOGCHR: DB 'L'-40H ;^L = Send logon 122H LSTCHR: DB 'P'-40H ;^P = Toggle printer 123H UNSAVE: DB 'R'-40H ;^R = Close input text buffer 124H TRANCHR: DB 'T'-40H ;^T = Transmit file to remote 125H SAVECHR: DB 'Y'-40H ;^Y = Open input text buffer 126H EXTCHR: DB '^'-40H ;^^ = Send next character 127H ; ; DS 2 ; 128H ; IN$MODCTL1: JMP CHKBUF DS 7 OUT$MODDATP: OUT MODDATP ! RET ;out modem data port 134H DS 7 IN$MODDATP: JMP READBUF DS 7 ANI$MODRCVB: ANI MODRCVB+MODRCFE ! RET ;bit to test for receive ready 148H CPI$MODRCVR: CPI MODRCVR ! RET ;value of rcv. bit when ready 14BH ANI$MODSNDB: ANI MODSNDB ! RET ;bit to test for send ready 14EH CPI$MODSNDR: CPI MODSNDR ! RET ;value of send bit when ready 151H DS 12 ;PMMI only calls 154H ; ; LOGONPTR: DW LOGON ;for user message. 160H DS 6 ; 162H JMP$GOODBYE: JMP GOODBYE ; 168H JMP$INITMOD: JMP INIT ;go to user written routine 16BH RET ! NOP ! NOP ;(by-passes PMMI routine) 16EH RET ! NOP ! NOP ;(by-passes PMMI routine) 171H RET ! NOP ! NOP ;(by-passes PMMI routine) 174H JMP$SETUPR: JMP SETUPR ; 177H JMP$SPCLMENU: JMP SPCLMENU ; 17AH JMP$SYSVER: JMP SYSVER ; 17DH JMP$BREAK: JMP SENDBRK ; 180H ; ; ; Do not change the following six lines. ; JMP$ILPRT: DS 3 ; 183H JMP$INBUF DS 3 ; 186H JMP$INLNCOMP: DS 3 ; 189H JMP$INMODEM DS 3 ; 18CH JMP$NXTSCRN: DS 3 ; 18FH JMP$TIMER DS 3 ; 192H ; ; ; The following clear the screen for the H19 or Sydmodem terminal ; CLREOS: CALL JMP$ILPRT ; 195H DB ESC,'J',0,0,0 ; 198H RET ; 19DH ; CLRSCRN: CALL JMP$ILPRT ; 19EH DB ESC,'E',0,0,0 ; 1A1H RET ; 1A6H ; ; SYSVER: CALL JMP$ILPRT ; 1A7H IF SMARTMODEM DB 'Version for Coleco Adam + Sydmodem 1200' ENDIF IF NOT SMARTMODEM DB 'Version for Sydmodem with 8250 I/O' ENDIF DB CR,LF,LF,'DEFAULT ',0 CALL BAUD CALL JMP$ILPRT DB ' BAUD' DB CR,LF,0 RET ; ;..... ; ; ;----------------------------------------------------------------------- ; ; NOTE: You can change the SYSVER message to be longer or shorter. The ; end of your last routine should terminate by 0400H (601 bytes ; available after start of SYSVER) if using the Hayes Smartmodem ; or by address 0C00H (2659 bytes) otherwise. ; ;----------------------------------------------------------------------- ; ; You can put in a message at this location which can be called up with ; CTL-O if TRANLOGON has been set TRUE. You can put in several lines if ; desired. End with a 0. ; LOGON: DB 'A content Adam user',CR,0 ;..... ; ; ; This routine sends a 300 ms. break tone to reset some time-share ; computers. ; SENDBRK: MVI A,40H ;SET BREAK TONE OUT MODDATP+3 JMP GOODBYE1 ;SEND A 300 MS. BREAK TONE ; ;..... ; ; ; This routine sends a 300 ms. break tone and sets DTR low for the same ; length of time to disconnect some modems such as the Bell 212A, etc. ; GOODBYE: DI XRA A OUT MODDATP+4 ;SET DTR AND RTS LOW MVI A,40H ;SET BREAK TONE OUT MODDATP+3 ; GOODBYE1: MVI B,3 ;WAIT 300 MS. CALL JMP$TIMER MVI A,03H ;RESET TO NORMAL 8 BITS OUT MODDATP+3 MVI A,09H OUT MODDATP+4 ;RESET DTR HIGH EI RET ;..... ; ; BAUD: LDA MSPEED CPI 1 JNZ BAUD1 CALL JMP$ILPRT DB '300',0 RET BAUD1: CPI 2 JNZ BAUD2 CALL JMP$ILPRT DB '450',0 RET BAUD2: CPI 3 JNZ BAUD5 CALL JMP$ILPRT DB '600',0 RET BAUD5: CPI 5 JNZ BAUD8 CALL JMP$ILPRT DB '1200',0 RET BAUD8: CALL JMP$ILPRT DB '9600',0 RET ; ; ; The following is used to initialize the SYDMODEM 8250 I/O port ; INIT: LDA MSPEED CPI 1 JZ OK300 CPI 2 JZ OK450 CPI 3 JZ OK600 CPI 5 JZ OK1200 CPI 8 JZ OK9600 INITMOD: MVI A,5 ;default transfer speed to 1200 baud STA MSPEED DI ;turn off interrupts for init. MVI A,0C9H ;RETURN STA 0020H ;I HOPE THIS DOES IT. SET$INT LXI H,INT$RTN SHLD 0039H MVI A,0C3H STA 0038H MVI A,1 OUT MODDATP+1 ;interrupt enable register MVI A,82H ;insure out of mode to set baud rate OUT MODDATP+3 ;line control register OUT MODDATP+3 ; LSPSPD: MVI A,01H ;default 'LSP' speed for 300 baud OUT MODDATP ;register for 'LSP' speed if enabled ; MSPSPD: MVI A,0H ;default 'MSP' speed for 1200 baud OUT MODDATP+1 ;register for 'MSP' speed if enabled ; MVI A,03H ;8-level, 1 stop bit, no parity OUT MODDATP+3 ;line control register MVI A,09H ;set 'DTR' for proper modem output level OUT MODDATP+4 ;modem control register DB 0EDH,056H EI RET ; READBUF: DI PUSH D PUSH H LDA READPOS LXI H,CBUFFER MOV E,A MVI D,0 DAD D ;INCREMENT READBUFFER POSITION INR A ANI BUFLEN STA READPOS ;PUT CHARACTER INTO A MOV A,M POP H POP D EI RET CHKBUF: PUSH H IN MODCTL1 CALL ANI$MODSNDB CALL CPI$MODSNDR JZ THRE THRF: MVI A,0 STA MODCTLBUF JMP INSPBUF THRE: STA MODCTLBUF INSPBUF: LXI H,WRITEPOS LDA READPOS CMP M JZ SETNOT1 SET1: MVI A,1 JMP EXIT$CHKBUF SETNOT1: MVI A,0 EXIT$CHKBUF: LXI H,MODCTLBUF ADD M POP H RET INT$RTN DI PUSH PSW IN MODCTL1 CALL ANI$MODRCVB CALL CPI$MODRCVR JNZ EXIT$INT ;VALID DATA PUSH H PUSH D LXI H,CBUFFER LDA WRITEPOS MOV E,A MVI D,0 DAD D GET$CHAR: IN MODDATP MOV M,A ADJ$WRPOS: LDA WRITEPOS INR A ANI BUFLEN STA WRITEPOS POP D POP H EXIT$INT: IN MODDATP POP PSW EI DB 0EDH,04DH MODCTLBUF DB 0 ;..... ; ; ; The following routine changes the baud rate for the SYDMODEM with the SET ; command. ; IF SMARTMODEM SETUPR: CALL JMP$ILPRT DB 'Select Baud Rate ( 300 1200 ) : ',0 LXI D,BAUDBUF ;point to input buffer for INLNCOMP CALL JMP$INBUF LXI D,BAUDBUF+2 ;compare BAUDBUF+2 w/chars below ENDIF ; SETUPR1: CALL JMP$INLNCOMP DB '300',0 JNC OK300 ;go if got match CALL JMP$INLNCOMP DB '450',0 JNC OK450 CALL JMP$INLNCOMP DB '1200',0 JNC OK1200 CALL JMP$ILPRT ;all matches failed - complain DB '++ INVALID BAUDRATE ++',CR,LF,BELL,0 JMP SETUPR ;try again ; IF NOT SMARTMODEM SETUPR: CALL JMP$ILPRT DB 'SELECT BAUD RATE (300, 450, 600, 1200, 9600): ',0 LXI D,BAUDBUF CALL JMP$INBUF LXI D,BAUDBUF+2 CALL JMP$INLNCOMP DB '600',0 JNC OK600 CALL JMP$INLNCOMP DB '9600',0 JNC OK9600 JMP SETUPR1 ENDIF ; OK300: MVI A,1 ;MSPEED 300 baud value LHLD BD300 ;get 300 baud parameters in HL JMP LOADBD ;go load them ; OK450: MVI A,2 LHLD BD450 JMP LOADBD ; OK600: MVI A,3 LHLD BD600 JMP LOADBD ; OK1200: MVI A,5 LHLD BD1200 JMP LOADBD ; OK9600: MVI A,8 LHLD BD9600 ; LOADBD: STA INITMOD+1 ;store speed to show transfer time MOV A,L ;get least significant baud rate byte STA LSPSPD+1 ;store in INITMOD MOV A,H ;get most signifcant baud rate byte STA MSPSPD+1 ;store in INITMOD JMP INITMOD ;reset SYDMODEM 8250 ; ; ; Table of baud rate parameters ; BD300: DW 0180H BD450: DW 0100H BD600: DW 00C0H BD1200: DW 0060H BD9600: DW 000CH ; BAUDBUF: DB 10,0 DS 10 ; ;----------------------------------------------------------------------- ; ; This routine can be used for your equipment, be sure to end with RET. ; If using the Hayes Smartmodem this is unavailable without a special ; change. ; SPCLMENU: RET ; ;----------------------------------------------------------------------- ; ; ; NOTE: MUST TERMINATE PRIOR TO 0400H (with Smartmodem) ; 0D00H (without Smartmodem) ; END